Comparison of condensation mode and Evaporative condensation scheme

Cold-cold condensation: air-air-cooled condenser (heat exchanges) -F them away with condensation and heat, rising air temperature-large air volume axis flowers-atmosphere
Water-cooled condensation: cooling water-water cooling condenser (heat exchange) -F them away with condensation and heat, increased water temperature increase-high-power cooling water pump-cooling water tower- (potential heat exchange) cooling tower fan-atmosphere atmosphere-atmosphere
Evaporating condensation (power-saving and air-conditioning condensate mode): condenser-evaporative condenser (heat exchange) -Setic heat and heat passed to water film-water film evaporation (submarine heat exchange)

”"

Evaporation of the board tube condensation
The solution is to use the heat of the high -temperature gaseous refrigerant inside the trail when the spraying water outside the trail is evaporated and the refrigerant inside the tube is gradually cooled by the gaseous tone to the liquid. The spray pipe at the top of the evaporative condenser is sprayed into the outer surface of the stainless steel condensate exhaust through the nozzle to form a thin water film. Some water in the water film evaporates the water vapor and the rest falls into the sink for Water pump recycles. The axis fans forced the air from the top and the lower part of the side wall to be inhaled. The water vapor in the atmosphere is controlled by the floating ball valve in the system to supplement cooling water. The cost of this solution is relatively high, and the nozzle can easily block the inconvenience of maintenance [1].

”"
Wet curtain evaporate condensation
Its solution uses special evaporation cooling wet curtains as the main material of condenser. The wet curtain uses special fiber materials and a variety of chemical materials. , Pour the water to the upper part of the wet curtain through the built -in water pump, and evenly moist the entire wet curtain contact surface. Through the fan, it quickly evaporates, which takes away a lot of heat, so that the temperature has dropped to the environment wet ball when the water flows to the lower part of the wet curtain. Temperature, cold water is replaced by high -efficiency heat exchangers and refrigerant. In most cases, the condensation temperature of the refrigerant can be reduced to less than 30 ° C. The cost of this solution is relatively low. In the later period of maintenance, only the wet curtain can be replaced every 2-3 years, which greatly reduces the maintenance cost